High Temperature – XB OEM – Series

High Temperature – XB OEM – Series

The ROTRONIC XB OEM-Series is the latest development in transmitters for humidity, temperature and dew point. One outstanding feature of this innovative product is the ability to confi gure the transmitter to meet the requirements of the application. Choose from a wide range of signal output types, probes, sensors and cable length.

Download Brochure

Request Quote
The ROTRONIC XB OEM-Series is the latest development in transmitters for humidity, temperature and dew point. One outstanding feature of this innovative product is the ability to confi gure the transmitter to meet the requirements of the application. Choose from a wide range of signal output types, probes, sensors and cable length.

Specifi cation

XB20

XB3

Power supply / Connections

Circuit type

2-wire loop powered

3-wire

Supply voltage VDC

10…28 VDC , V min = 10 V + (0.02 x Load*) *Load resistance in ohms

15…40 VDC or 12…28 VAC

Output signal type

4…20 mA

0…1V, 0…5V, 0…10V,
0…20 mA, 4…20 mA

Nominal current consumption

2 x 20 mA

< 50 mA

Electrical connections

Terminal block

Polarity protection

Protective diode on V+

Humidity measurement

Sensor

Hygromer® IN-1

Measurement range

0…100 %rh

Measurement accuracy at 23 °C

±1.0 %rh

Repeatability

0.3 %rh

Long term stability

< 1 %rh / year

Temperature measurement

Sensor (Standard)

Pt100 RTD, IEC 751 1/3 class B

Measuring range

-100…200 °C (see also environmental limits)

Measurement accuracy at 23 °C

±0.2 °C

Repeatability

0.05 °C

Long-term stability

< 0.1 °C / year

Calculated parameters

Psychrometric calculations

Dew or frost point (user confi gurable option)

Environmental limits

Storage and transit

-50…+70 °C, 0…100 %rh, non condensing

Operating limits at electronics

-40… +85 °C, 0…100 %rh, non condensing

Maxi. humidity /temperature
at sensor

See humidity/temperature window of sensor

Maximum air velocity at probe

40 m/s (7,870 ft /min) – depends on dust fi lter type

Digital interface (service connector)

Interface type

UART (Universal Asynchronous Receiver Transmitter)

Maximum service cable length

5 m (16.4 ft)

Firmware update

Via service connector, requires HW4 software

Start-up time and data refresh rate

Start-up time

3.4s (typical)

1.9s (typical)

Data refresh rate

3.4s (typical)

1.7s (typical)

Conformity with standards

CE / EMC immunity

EMC Directive 2004/108/EG:
EN 61000-6-1: 2001 EN 61000-6-2: 2005
EN 61000-6-3: 2005, EN 61000-6-4: 2001 + A11

Solder type

Lead free (RoHS directive)

FDA / GAMP directives

compatible