Useful electrical stroke (C.E.U.) |
10/25/50/75/100 |
Independent linearity (within C.E.U.) |
see table |
Displacement speed |
≤ 10 m/s |
Displacement force |
≤ 4N |
Vibrations |
5…2000Hz, Amax =0,75 mm amax. = 20 g |
Shock |
50 g, 11ms. |
Tolerance on resistance |
± 20% |
Recommended cursor current |
< 0,1 μA |
Maximum cursor current |
10mA |
Maximum applicable voltage |
see table |
Electrical isolation |
>100MΩ at 500V=, 1bar, 2s |
Dielectric strength |
< 100 μA at 500V~, 50Hz, 2s, 1bar |
Dissipation at 40°C (0W at 120°C) |
see table |
Actual Temperature Coefficient of the output voltage |
< 1,5ppm/°C |
Working temperature |
-30…+100°C |
Strorage temperature |
-50…+120°C |
Case material |
Anodised aluminium Nylon 66 G25 |
Control rod material |
Stainless steel AISI 303 |
Fixing |
Brackets with variable longitudinal axis |
1 Spring loaded – PY2 Rectilinear Displacement Transducer
FEATURES & APPLICATIONS:
- 10 to 100 mm. stroke
- Double support of the control rod and return spring
- Tip with M2.5 thread and stainless steel ball
- Independent linearity up to ± 0,1%
- Infinite resolution
- No variation of electrical signal outside theoretical electrical stroke
- Displacement speed up to 10 m/s
- Working temperature: -30…+100°C
- Electrical connections: PY2 F 3 wire 1m screened cable, PY2 C 5-pole connector DIN43322
- Life duration: > 100×106 operations (within C.E.U.)
- Grade of protection IP40
- Suitable for use in explosive environments with presence of gas (groups IIA, IIB, IIC) and combustible powders.
Standards for simple device: ATEX CEI EN 50020 2003 – paragraph 5.4 a