KS transmitters are based on film sensing element deposited on stainless steel diaphragm.
Thanks to the latest state of the art SMD electronics and compact all stanless steel construction, these products are extremely robust and reliable, with SIL2 certification supplied as standard.
KS transmitters are suitable for all industrial applications, specially on hydraulics (presses, pumps, power pack, fluid power, etc.) with severe conditions usually with high level of shock, vibration, and pressure and temperature peaks.
Output signal |
VOLTAGE |
CURRENT |
Non Linearity (BFSL) |
± 0.15% FS (typ) ± 0.25% FS (max) |
|
Hysteresis |
+ 0.1% FS (typ) + 0.15% FS (max) |
|
Repeatability |
± 0.025% FS (typ) ± 0.05% FS (max) |
|
Zero offset tolerance |
± 0.15% FS (typ) ± 0.25% FS (max) |
|
Span offset tolarance |
± 0.15% FS (typ) ± 0.25% FS (max) |
|
Accuracy at room temperature (1) |
< ± 0.5% FS |
|
Pressure ranges (2) |
From 1 bar to 1000 bar (See table) |
|
Resolution |
Infinite |
|
Overpressure (without degrading performance) |
See table |
|
Pressure containment (burst test) |
See table |
|
Pressure Media |
Fluids compatible with Stainless Steel AISI 430F and 17-4 PH |
|
Housing |
Stainless Steel AISI 304 |
|
Power supply |
15…30Vdc |
10…30Vdc |
Non Linearity (BFSL) |
250 Vdc |
|
Zero output signal |
0 V (N); 0.1 V (C) |
4 mA (E) |
Full scale output signal |
10 V (N); 10.1 V (C) |
20 mA (E) |
Allowed load |
≥ 5KΩ |
see load diagram |
Long term stability |
< 0.2% FS/per year |
|
Operating temperature range (process) |
-40…+125°C (-40…+257°F) |
|
Operating temperature range (ambient) |
-40…+105°C (-40…+221°F) |
|
Compensated temperature range |
-20…+85°C (-4…+185°F) |
|
Storage temperature range |
-40…+125°C (-40…+257°F) |
|
Temperature effects over compensated range (zero) |
± 0.01% FS/°C typ. (± 0.02% FS/°C max.) |
|
Temperature effects over compensated range (span) |
± 0.01% FS/°C typ. (± 0.02% FS/°C max.) |
|
Response time (10…90%FSO) |
< 1 msec |
|
Warm-up time (3) |
< 30 sec. |
|
Mounting position effects |
Negligible |
|
Humidity |
Fino a 100%RH non-condensing |
|
Weight |
80-120 gr. nominal |
|
Mechanical shock |
100g/11msec according to IEC 60068-2-27 |
|
Vibrations |
20g max at 10…2000 Hz according to IEC 60068-2-6 |
|
Ingress protection |
IP65/IP67 |
|
Output short circuit and reverse polarity protection |
YES |
|
CE Conformity |